Amteco AWR-2:
 $45.00 - 1 Gallon

CLEAR ACRYLIC LACQUER WATER REPELLENT CONCRETE, MASONRY AND AGGREGATE SURFACE SEALER
Product Description:
A water clear 100% acrylic solution surface lacquer sealer for exterior and interior use on concrete, masonry, and aggregate surfaces.  The resin has superior ultra violet light resistance and does not yellow on exterior exposures.  It is specifically designed for ease of maintenance due the ability to redissolve into itself when recoating after aging.  The film has superior resistance to traffic and most water and oil based common chemicals.  Properly sealed surfaces have excellent food stain resistance.  Available in satin, gloss, and black (for asphalt).
Product Uses:
Decorative and uncolored concrete aggregate finishes, terracotta tiles, concrete, interior and exterior concrete floors, bricks, driveways, precast exterior aggregate construction panels, patio blocks, asphalt, stone, cast limestone sandstone and stucco.
Physical Properties:
| |
AWR 2-2 |
AWR 2-SAL (VOC Compliant) |
| Weight per gal. |
7.4-7.6 lbs. |
10.1-10.4 lbs. |
| Flash Point |
110F |
140F |
| Non Vol. Solids |
14.1 - 14.3% |
12.1 - 12.4% |
| VOC |
774 gr/liter |
493 gr/liter |
| Main Solvent |
SC 100 |
PerChloroethylene |
| Clean-Up Sol. |
Xylol |
Xylol |
Spread Rate:
| Apply 2 coats to most surfaces, 3 if extremely porous. |
| New smooth concrete floors |
300-400 sq. ft / gal |
| Old porous surfaces |
175-225 sq. ft / gal |
| Extremely porous decking and vertical siding |
125-175 sq. ft / gal |
| Pavers |
80-100 sq. ft / gal |
| Cast limestone or cast stone |
100-150 sq. ft / gal |
| Split Face |
50-75 sq. ft / gal |
Surface Preparation:
Remove dust, grease and oil deposits.  New floor installations should age a minimum of 60 days.  Exterior concrete floor surfaces, (particularly new surfaces) which are steel trowel finished, should be acid etched to insure proper penetration and adhesion.  The surface must be thoroughly raised after etching to remove excess salts.  Surface must be thoroughly dry for 48 hours to prevent peeling.  Surface temperature must be above dew point.
Application:
AWR is best applied by spray in thin surface wetting coats.  The first coat in intended to penetrate deeply and should almost disappear into the substrate.  (On extremely smooth or hard substrate one coat should be enough).  The second coat will redissolve the first coat and drive it deeper into the substrate.  A uniform slight sheen might result after the second coat.  A third coat may be required on very porous substrates.
The porosity and temperature of the substrate are important influences on exact amount of sheen obtained and resulting surface wear characteristics.  Porosity of the substrate will determine amount of product needed for each coat.
CAUTION:  Respirators must be worn when applying these materials.  Do not smoke or apply near open flame.  See Material Safety Data Sheet for additional safety handling information.
Surface must be thoroughly dry for 24 hours.  If moisture remains, white spots and/or disbonding may result.  Remove spots with Trimethyl benzene then apply another light coat.  If material is applies in a heavy single coat, peeling, disbonding and premature wear patterns may result.
AWR can be applied by brush, roller or spray.  AWR2-SAL can applied in the same manner.  If surface temperature is above 80 degrees F, apply by spray only.  Equipment must be compatible with Penalomethane (equipped with Viton/Teflon and stainless steel parts).
A: Roller Application:  Use 3/8" Pronell nap or standard 1/4" nap other for paint roller applications.  Apply the material by pushing the roller up and back in a vertical direction.  Do not apply side to side roll with the broom strokes of the concrete).  Roll quickly so as not to allow product to cure on the surface before penetrating into the substrate.  Allow first coat to dry 2 to 4 hours before applying a second coat.
B: Spray Applications:  Spray light coat with 50% overlapping strokes.  Wait 2 to 4 hours before spraying second coat.  slight sheen might show after show after second coat is applies.  Uniformity of sheen will depend on the uniformity of the porosity and application technique.  Recommended spray tips and pressure 0.017-0.019, tip orifice at 900-1200 p.s.i.  After 24 hour cure, flood AWR treated surface with water to ensure water seal.  Mark dark area indicating water penetration.  After 24-48 hour dry time, apply AWR to marked areas and repeat process to ensure water seal if necessary.
DO NOT LEAVE PUDDLES ON HORIZONTAL SURFACES!
Dry Time:
30 min. at 77f. Dry hard; 1-2 hours. Recoat, 2 hours.
Thinning & Cleaning:
Thinning not required except during high temperatures.  Thin with 1 qt. xylol per gallon when surface temperature exceeds 95 degrees.  Use xylol for equipment cleanup.
Recommended for driveways, garage & basement floors, brick, stone & concrete
walkways & patios.  Eliminates water, soil & oil absorption into the
surface when properly applied.  Available in: satin or glossy finishes
(glossy by special order only).
AWR MSDS Sheet:
 Amteco AWR-2
Amteco AWR-2: